Customer complaint

What the customer noticed

The air conditioner started and stopped at random and sometimes froze over.

Diagnostic findings

What inspection and testing revealed

Compressor and fan tests were normal. The freeze sensor had come loose from the evaporator coil. Moving the control box interrupted operation even though the accessible electrical connections were secure, indicating an internal control-box fault.

Work performed or recommended

What Sunset did or recommended

Reattached the freeze sensor, replaced the control box, and monitored the air conditioner for more than 20 minutes.

Outcome and next step

Where the service call stands

The air conditioner operated without further interruptions during the observation period.